Análise comparativa do desempenho de sistemas fotovoltaicos: microinversor versus inversor string com otimizadores de potência no IFPE – Campus Recife
| dc.contributor.advisor | Cirilo, Rodrigo de Paiva | |
| dc.contributor.advisor-co | Oliveira, Gideão Paulo de | |
| dc.contributor.advisor-coLattes | http://lattes.cnpq.br/4863269022451736 | |
| dc.contributor.advisorLattes | http://lattes.cnpq.br/5913937446624081 | |
| dc.contributor.author | Santos, Rhayanna Larissa Ferreira dos | |
| dc.contributor.authorLattes | http://lattes.cnpq.br/1023046982055964 | |
| dc.date.accessioned | 2026-08-31T18:15:24Z | |
| dc.date.issued | 2025-12-29 | |
| dc.degree.departament | UACSA | |
| dc.degree.graduation | Engenharia Elétrica | |
| dc.degree.level | bachelor's degree | |
| dc.degree.local | Cabo de Santo Agostinho | |
| dc.description.abstract | O crescimento da demanda global por energia elétrica e a necessidade de reduzir impactos ambientais impulsionaram o avanço das fontes renováveis, especialmente a energia solar fotovoltaica. Nesse contexto, compreender o desempenho de diferentes arquiteturas de conversão como inversores string com otimizadores e microinversores tornou-se essencial para aprimorar a eficiência de sistemas de geração distribuída. Embora a literatura reconheça o potencial dos dispositivos Module Level Power Electronics (MLPE) em cenários de sombreamento e mismatch, ainda há lacunas quanto ao comportamento comparativo dessas tecnologias quando instaladas sob condições idênticas de irradiação e disposição física. Este trabalho teve como objetivo avaliar de forma comparativa o desempenho operacional de duas usinas fotovoltaicas localizadas em Recife-PE, sendo uma equipada com inversor string associado a otimizadores (UFV-ISO) e outra utilizando microinversor (UFV-M). A análise concentrou-se nos principais indicadores de performance recomendados pela literatura: Produtividade Específica (Yf), Rendimento de Referência (Yr), Performance Ratio (PR) e Fator de Capacidade (FC), a partir de dados reais de geração registrados entre setembro a novembro de 2025. Foram feitas coletas dos dados de produção elétrica dos sistemas, na obtenção da irradiação solar média mensal via plataforma SunData/CRESESB e na aplicação das equações normativas para cálculo dos indicadores de desempenho. Ambos os sistemas foram instalados no mesmo telhado, com igual orientação e inclinação, garantindo condições controladas para fins de comparação direta. Os resultados mostram que os dois sistemas apresentaram comportamento coerente com a sazonalidade da irradiação local e desempenho superior às médias usuais da literatura para regiões brasileiras de alta insolação. Apesar da elevada semelhança entre as curvas de desempenho, observou-se uma discreta predominância do sistema UFV-ISO, que apresentou valores marginalmente superiores nos índices ao longo dos três meses analisados. As diferenças observadas, inferiores a 1%, caracterizam variações pouco significativas do ponto de vista operacional, indicando que ambas as tecnologias operaram de forma eficiente e estável nas condições estudadas. Nesse contexto, embora o sistema com otimizadores tenha apresentado desempenho levemente superior, o microinversore demonstra desempenho equivalente e plenamente adequado à geração de energia. Os resultados reforçam que a escolha entre os dois sistemas deve considerar não apenas os indicadores energéticos, mas também aspectos como complexidade de instalação, manutenção e estratégias específicas de mitigação de sombreamento. | |
| dc.description.abstractx | The growth in global electricity demand and the need to reduce environmental impacts have driven the advancement of renewable energy sources, particularly solar photovoltaic energy. In this context, understanding the performance of different conversion architectures, such as string inverters with power optimizers and microinverters, has become essential to improve the efficiency of distributed generation systems. Although the literature recognizes the potential of Module Level Power Electronics (MLPE) devices in scenarios involving shading and module mismatch, there are still gaps regarding the comparative behavior of these technologies when installed under identical irradiation conditions and physical arrangements.This study aimed to comparatively evaluate the operational performance of two photovoltaic power plants located in Recife, Brazil. One system is equipped with a string inverter associated with power optimizers (UFV-ISO), while the other employs microinverters (UFV-M). The analysis focused on the main performance indicators recommended in the literature: Specific Yield (Yf), Reference Yield (Yr), Performance Ratio (PR), and Capacity Factor (CF), based on real generation data recorded between September and November 2025.Data collection involved gathering electrical production data from both systems, obtaining the average monthly solar irradiation through the SunData/CRESESB platform, and applying the standard equations for calculating performance indicators. Both systems were installed on the same rooftop, with identical orientation and tilt, ensuring controlled conditions for direct comparison.The results show that both systems presented behavior consistent with the seasonality of local solar irradiation and performance levels above the typical averages reported in the literature for Brazilian regions with high solar potential. Despite the strong similarity between the performance curves, a slight predominance of the UFV-ISO system was observed, presenting marginally higher index values throughout the three analyzed months.However, the differences observed, which were below 1%, represent variations that are operationally insignificant, indicating that both technologies operated efficiently and stably under the studied conditions. In this context, although the system with power optimizers showed slightly superior performance, the microinverter system demonstrated equivalent performance and proved fully suitable for electricity generation. The results reinforce that the choice between these two systems should consider not only energy performance indicators but also aspects such as installation complexity, maintenance requirements, and specific strategies for shading mitigation. | |
| dc.format.extent | 76 f. | |
| dc.identifier.citation | SANTOS, Rhayanna Larissa Ferreira dos. Análise comparativa do desempenho de sistemas fotovoltaicos: microinversor versus inversor string com otimizadores de potência no IFPE – Campus Recife. 2026. 76 f. Trabalho de Conclusão de Curso (Graduação em Engenharia Elétrica) - Unidade Acadêmica do Cabo de Santo Agostinho, Universidade Federal Rural de Pernambuco, 2025. | |
| dc.identifier.uri | https://arandu.ufrpe.br/handle/123456789/9157 | |
| dc.language.iso | pt_BR | |
| dc.publisher.country | Brazil | |
| dc.publisher.initials | UFRPE | |
| dc.rights | openAccess | |
| dc.rights.license | Attribution-NonCommercial-NoDerivatives 4.0 International | en |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
| dc.subject | Energia solar - Produção | |
| dc.subject | Energia solar - Índices | |
| dc.subject | Inversores elétricos | |
| dc.subject | Conversores de frequência | |
| dc.title | Análise comparativa do desempenho de sistemas fotovoltaicos: microinversor versus inversor string com otimizadores de potência no IFPE – Campus Recife | |
| dc.type | bachelorThesis |